 Dual rotation manipulator motorization ready
Customer Request: A manufacturer of thin film deposition tools was looking to replace a bellows-based, dual rotary, UHV manipulator from another supplier with a UHV, magnetically-coupled manipulator. The application is for indexing and rotating PLD targets in a Physical Vapor Deposition system. Motor mounts and couplings were required for installation of customers motors
Provided: Dual Rotational Hollow-shaft, Magnetically-coupled manipulators have been provided. Units with a wide variety of rotating tube and inner shaft diameters and shaft extension lengths meet each system requirement.
|
|
 Motorized, heavy duty manipulators lift 500 lb inner container
Customer Request: The ultimate goal of this project was to allow the users to study materials which had been introduced and frozen onto plates at liquid nitrogen temperatures (77k). In order to do this, gases would be introduced into the vacuum system which would freeze onto the plates. A second chamber within the vacuum system, which was also cooled, would then be lowered to separate the vacuum system into two distinct volumes. The materials trapped on the plates would then be studied as the temperature of the plates was raised. The material being studied was radioactive, therefore, the customer did not want to use welded bellows (which could rupture) or any other vacuum seals with a potential to leak.
Provided: Transfer Engineering developed heavy duty magnetic manipulators to allow the large inner shroud to be positioned within the vacuum system. Six of these manipulators were used, each with a coupling force of 180 lbs. They are driven up and down with a large motor, leadscrew drive mechanism and a simple motion control system. |